PAS-DALLAS
• passive transponder 125 kHz
• work with DALLAS key readers CZ-DALLAS

• passive transponder 125 kHz
• work with DALLAS key readers CZ-DALLAS
• RS-485 ACCO system bus to PC USB connection
• reader socket for ACCO-USB-CZ system management reader
• powered by USB port
• Plug&play installation
• 4 detection circuits
• built-in LCD for easy day-to-day operation and system programming
• supports remote panels and virtual panels (using CSP-ETH interface)
• 4 control inputs with functionality programmed by the installer
• 4 outputs programmed by the installer which enable interaction with other systems
• supports fire and damage transmission devices
• built-in backup power supply interfacing with a single battery 12 V and AUX 24 V and 18 V power outputs 24 V i 18 V
• A1R heat detector in conformance with EN54-5
• simple installation of the detector at the base of DB-100
• possibility of connecting an external status indicator
• support for up to 255 access control modules
• ability to create up to 255 partitions in 1 control panel (up to 255 access control modules can be defined in one partition)
• ability to add up to 16 passageways (up to 16 partitions can be defined in each passageway)
• 8 programmable zones on the control panel board, expandable to 264 zones
• 8 programmable outputs on the control panel board, expandable to 264 outputs
• 2 high-current outputs on the control panel mainboard, with power output functionality (current-carrying capacity of each output: 0.5 A / 12 V DC ± 15%)
• ability to connect up to 32 expanders directly to the control panel: INT-E, INT-O, INT-PP, INT-RX-S
• electrical protection of all zones and outputs as well as communication buses
• connector for APS-412 or APS-612 backup power supply
• USB MINI-B port for configuring network settings and updating firmware of the control panel without having to disassembly it
• LED status indicators for:
○ communication between the control panel and the RS-485 buses, computer and server
○ power supply circuit
○ microSD card
• events are stored in non-volatile memory of the control panel:
○ up to 1,000,000 events from the control panel
○ 100,000 events from each access control module
• number of users: 8,000 in the control (65,000 in the whole system)
• each user can be assigned:
○ code
○ passive transponder (e.g. in the form of proximity card or key tag)
○ Dallas chip (iButton)
○ remote control keyfob
• ability to assign 4 identifiers and 1 keyfob to a single user
• access to certain partitions within a specified time interval
• ability to block/unblock partition at a specified time, or as per access schedule
• implementation of logic functions on zones and outputs
• support for turnstiles
• ability to control the control panel outputs by using keyfobs
• optional installation of the control panel in OPU-3 P or OPU-4 P enclosureSATEL failure to the control panel (INTEGRA Firmware 1.16 or newer)
• TCP/IP reporting receiver for SATEL Ethernet and GPRS transmitters
• support for up to 256 subscribers with individual link supervision
• hardware event buffering
• ETHERNET link supervision
• optional incoming events filtering based on physical address (MAC)
• support for automatic IP address configuration with DHCP
• possibility to install in computer's PCI slot
• built-in LCD for easy day-to-day operation and system programming,
• built-in backup power supply with a single battery 12 V 17 Ah, and AUX 24 V and 18 V power outputs
• selection of 32 signal sounds
• possibility of emitting two different sounds
• volume control
• high base for installation in installation tubes
• operation in Windows environment
• operation at a frequency of 125 kHz
• 10 workstations license for STAM-2 software
• unique Swirl chamber accelerates smoke detection
• test fires detected: TF-2 to TF-5 acc. to EN54-7 and TF-1 and TF-8 acc. to ISO/TS 7240-9:2006
• stainless-steel precision filter
• failure signalling – contamination of measuring chamber
• simple detector installation at the base of DB-100
• possibility of connecting an external status indicator
• supports DMP-100, DRP-100 and DCP-100 detectors
• a detector may be locked in the mounting base which prevents it from being dismantled without the use of tools,
• additional earth cable clamp (PE) which facilitates the mounting of the system using shielded cables
• support for cards, tags and other 125 kHz passive transponders
• system management reader for easy proximity cards management via ACCO software
• LED indicator for reader state indication
• built-in buzzer for acoustic feedback
• RJ-45 connector for connecting to ACCO-USB
• 4 detection circuits
• supports remote and virtual panels (using CSP-ETH interface)
• 4 control inputs with functionality programmed by the installer
• 4 outputs programmed by the installer which enable interaction with other systems
• supports fire and damage transmission devices
• built-in backup power supply interfacing with a single battery 12 V and AUX 24 V and 18 V power outputs
• unique Swirl chamber accelerates smoke detection
• test fires detected: TF-1 to TF-5 acc. to EN54-7 and TF-1, TF-6 and TF-8 acc. to ISO/TS 7240-9:2006
• A1R heat detector in conformance with EN54-5
• stainless-steel precision filter
• failure signalling – contamination of measuring chamber
• simple detector installation at the base of DB-100
• possibility of connecting an external status indicator