• triggers panic alarm and remote notification for hold-up situation
• compatibility with all panels supporting NC zones

• triggers panic alarm and remote notification for hold-up situation
• compatibility with all panels supporting NC zones
• full compliance with EN 50131 Grade 2
• acoustic signalling: piezo
• optical signalling: LED
• inner metal shield
• tamper protection against:
○ removal from mounting
○ lid opening
• optional 12 V 2,3 Ah battery
• built-in level to facilitate aesthetic mounting
• 8 monitoring triggering or message inputs
• dedicated inputs for alarm system failure signals
• dedicated input for AC power supply monitoring
• 4 outputs with remote control option
• automatic switching to SMS in case of lack of GPRS signal
• SMS/CLIP messaging
• sending test transmission using CLIP
• communication failure signalling
• built-in 2 A buffer power supply
• two separate, programmable channels
• support for up to 340 keyfobs
• operating range up to 200 m open space
• remote low battery indication
• arm/disarm/reset confirmation
• RS-232 for programming and keyfob management
• 4-channel
• KEELOQ® dynamic code-hopping technology
○ ideal for security demanding applications
○ high immunity to interference signals
• SAW Resonator frequency stabilization
○ immunity to environmental changes
• powered by single A23 12 V battery
• high efficiency mains powered switching mode power supply with 24 V DC output
• 5 A power supply capacity
• short circuit, overload and overheat protection
• desgined for use with sealed lead-acid batteries
• current controlled battery charging circuit
• battery deep discharge protection
• 4 OC outputs for remote supervision
• optical indication for mains, battery, overload and overheating status
• acoustic failure indication
• dedicated to powering ASP-100 and MSP-300 sirens
• voltage 3.6 V
• capacity 13 Ah
• operating temperature range from -55°C to +85°C
• over 5-year lifetime (if used at temperature up to 30°C)
• low self-discharge rate (<1% per year at 20°C)
• short-circuit protection
• resistance to harsh working conditions
• set with a converter for programming devices equipped with RS-232 TTL with RJ or PIN-3 connector, length 4m (CA-5, CA-6, RX-2K, RX-4K, RXH-1K, RXH-2K, RXH-4K, RE-4K, ACCO-KP, ACCO-KP-PS, ACCO-KPWG, ACCO-KPWG-PS, ACTIVA, GPRS-T1, GPRS-T2, GPRS-T4, GPRS-T6, MICRA, VERSA)
• support for single door with entry and exit authorization
• support for SATEL terminals and for WIEGAND compatible terminals
• standalone or ACCO/ACCO NET system operation mode
• 1,024 users
• user rights definition
• access authorization with proximity card and/or code
• biometric authorization
• 256 schedules
• holiday schedules
• non-volatile 24,576 event log
• work time registration event tagging
• anti-passback
• programming means:
○ permanently or temporarily connected LCD keypad
○ PC connected via RS-232 port
○ PC connected via ACCO-USB interface to RS-485 bus
• non volatile settings memory
• FLASH based firmware update
• scheduled door locking and unlocking
• programmable limits on number of accesses
• switching mode backup power supply 12 V DC 1.2 A
• access authorization with code and/or proximity card
• support for cards, tags and other 125 kHz passive transponders
• LED indicators for door and controller status indication
• built-in buzzer for acoustic feedback
• keys backlight
• optical tamper protection
• doorbell button
• indoor and outdoor operation
• operation in Windows environment
• operation at a frequency of 125 kHz
• 10 workstations license for STAM-2 software
• unique Swirl chamber accelerates smoke detection
• test fires detected: TF-2 to TF-5 acc. to EN54-7 and TF-1 and TF-8 acc. to ISO/TS 7240-9:2006
• stainless-steel precision filter
• failure signalling – contamination of measuring chamber
• simple detector installation at the base of DB-100
• possibility of connecting an external status indicator
• supports DMP-100, DRP-100 and DCP-100 detectors
• a detector may be locked in the mounting base which prevents it from being dismantled without the use of tools,
• additional earth cable clamp (PE) which facilitates the mounting of the system using shielded cables
• detection of water flood in the areas with water installations
• easy to install external sensor
• acoustical signaling: piezo transducer
• tamper protection against opening
• telephone line monitoring conversion to TCP/IP transmission, compatible with any panel
• 8 zones for triggering of TCP/IP reporting
• support for SSL encryption protocol during communication with the outgoing mail server (only ETHM-2 FLASH v2.00)
• remote control via web browser (only ETHM-2 FLASH v1.02)
• unit configuration via ETHM-2 SOFT
• local configuration via RS-232
• encrypted data transmission
• 4 independent channels with a relay output
• Outputs can be configured for monostable mode (on time) or bistable mode (On/Off)
• Support for up to 340 key fobs which can be managed using PC computer
• Key fob low battery indication
• Acknowledgement of arming / disarming
• PC configuration
• Operating range up to 300 m in open area
• 2-channel
• KEELOQ® dynamic code-hopping technology
○ ideal for security demanding applications
○ high immunity to interference signals
• SAW Resonator frequency stabilization
○ immunity to environmental changes
• powered by single 12 V battery
• EN50131-6 Grade 2 compliant
• high efficiency mains powered switching mode power supply with 12 V DC output
• 10 A power supply capacity
• short circuit, overload and overheat protection
• desgined for use with sealed lead-acid batteries
• current controlled battery charging circuit
• battery deep discharge protection
• 4 OC outputs for remote supervision
• optical indication for mains, battery, overload and overheating status
• acoustic failure indication
• user authorization by code or card
• support for up to 50 users
• module configuration from the keypad
• LEDs to indicate module status
• illuminated keys for easy operation in darkness
• built-in relay for direct control of bolt or lock
• totally enclosed for outdoor mounting on the outside
• set for programming devices equipped with RS-232 Port with RJ or PIN-5 connector (INTEGRA, CA-10 P, GSM-4, GSM LT-1, GSM LT-2, ACU-100, VIVER, ETHM-2)
• support for single door with entry and exit authorization
• support for SATEL terminals and for WIEGAND compatible terminals
• standalone or ACCO/ACCO NET system operation mode
• 1,024 users
• user rights definition
• access authorization with proximity card and/or code
• biometric authorization
• 256 schedules
• holiday schedules
• non-volatile 24,576 event log
• work time registration event tagging
• anti-passback
• programming means:
○ permanently or temporarily connected LCD keypad
○ PC connected via RS-232 port
○ PC connected via ACCO-USB interface to RS-485 bus
• non volatile settings memory
• FLASH based firmware update
• scheduled door locking and unlocking
• programmable limits on number of accesses
• large, easy to read backlit LCD display
• access authorization with code and/or proximity card
• support for cards, tags and other 125 kHz passive transponders
• LED indicators for door and controller status indication
• built-in buzzer for acoustic feedback
• display and keypad backlight
• tamper protection
• support for cards, tags and other 125 kHz passive transponders
• system management reader for easy proximity cards management via ACCO software
• LED indicator for reader state indication
• built-in buzzer for acoustic feedback
• RJ-45 connector for connecting to ACCO-USB
• 4 detection circuits
• supports remote and virtual panels (using CSP-ETH interface)
• 4 control inputs with functionality programmed by the installer
• 4 outputs programmed by the installer which enable interaction with other systems
• supports fire and damage transmission devices
• built-in backup power supply interfacing with a single battery 12 V and AUX 24 V and 18 V power outputs
• unique Swirl chamber accelerates smoke detection
• test fires detected: TF-1 to TF-5 acc. to EN54-7 and TF-1, TF-6 and TF-8 acc. to ISO/TS 7240-9:2006
• A1R heat detector in conformance with EN54-5
• stainless-steel precision filter
• failure signalling – contamination of measuring chamber
• simple detector installation at the base of DB-100
• possibility of connecting an external status indicator
• DB-100 socket can be surface mounted
• PG-16 cable glands or Ø16 tubes can be used
• external mounting clips enable the installation without the need to perforate the bottom of the base
• DB-100 socket is additionally protected against water seeping in from the ceiling
• adjustment and testing device for INDIGO detectors
• simulates plate, laminated and temperature glass breaking sound
• allows precise adjustment of detector for a particular installation location
• powered by single 6LR61 alkaline battery
• acoustic alarm: piezoelectric transducer
• tamper protection against opening / detaching from the mounting surface
• emergency power supply with 9V battery
• interfaces PSTN devices with ISDN network
• shares ISDN network with other devices (telephones, fax machines, modems)
• optional priority alarm calls
• support for point-to-point and point-to-multipoint mode configurations
• external modem functionality for INTEGRA panels
• RS-232 port for panels upload/download
• output for optional line separation module
• 2 independent channels with a relay output
• Outputs can be configured for monostable mode (on time) or bistable mode (On/Off)
• Support for up to 340 key fobs which can be managed using PC computer
• Key fob low battery indication
• Acknowledgement of arming / disarming
• PC configuration
• Operating range up to 300 m in open area
• 4-channel
• KEELOQ® dynamic code-hopping technology
○ ideal for security demanding applications
○ high immunity to interference signals
• SAW Resonator frequency stabilization
○ immunity to environmental changes
• powered by single 12 V battery
• 230 V/20 V AC, 40 VA
• for OPU-3 P and OPU-4 P enclosures
• facilitates installation of low-voltage installations, like alarm installations
• screw type terminals
• GSM quad-band antenna for GSM-4, GSM LT-1 and GSM LT-2, GPRS-T1, GPRS-T2, INTEGRA 128-WRL modules, mounted to the case
• support for single door with entry and exit authorization
• standalone or ACCO/ACCO NET system operation mode
• 1024 users
• user rights definition
• access authorization with proximity card and/or code
• 256 schedules
• holiday schedules
• non-volatile 24 576 event log
• work time registration event tagging
• anti-passback
• programming means:
○ permanently or temporarily connected LCD keypad
○ PC connected via RS-232 port
○ PC connected via ACCO-USB interface to RS-485 bus
• non volatile settings memory
• FLASH based firmware update
• scheduled door locking and unlocking
• programmable limits on number of accesses
• switching mode backup power supply 12 V DC 1.2 A
• passive transponder 125 kHz
• work with DALLAS key readers CZ-DALLAS
• RS-485 ACCO system bus to PC USB connection
• reader socket for ACCO-USB-CZ system management reader
• powered by USB port
• Plug&play installation
• 4 detection circuits
• built-in LCD for easy day-to-day operation and system programming
• supports remote panels and virtual panels (using CSP-ETH interface)
• 4 control inputs with functionality programmed by the installer
• 4 outputs programmed by the installer which enable interaction with other systems
• supports fire and damage transmission devices
• built-in backup power supply interfacing with a single battery 12 V and AUX 24 V and 18 V power outputs 24 V i 18 V
• A1R heat detector in conformance with EN54-5
• simple installation of the detector at the base of DB-100
• possibility of connecting an external status indicator
• LED visual signalling system
• aesthetic appearance suitable for the majority of interiors
• simple installation
• microprocessor controlled
• acoustical signaling: dynamic horn
• optical signaling: ultra bright LEDs
• inner metal shield
• tamper protection against opening and removing from mounting surface
• support for sealed lead acid back up battery
• available also in blue (SD-3001 BL) and orange (SD-3001 O)
• 5 inputs for triggering of reporting or personal messaging
• automatic fallback to SMS reporting in case of GPRS failure
• SMS/CLIP personal messaging
• remote control of module's output
• support for CLIP test transmissions
• communication failure indication
• four separate, programmable channels
• support for up to 340 keyfobs
• operating range up to 200 m open space
• remote low battery indication
• arm/disarm/reset confirmation
• RS-232 for programming and keyfob management
• 2-channel
• KEELOQ® dynamic code-hopping technology
○ ideal for security demanding applications
○ high immunity to interference signals
• SAW Resonator frequency stabilization
○ immunity to environmental changes
• powered by single A23 12 V battery
• EN50131-6 Grade 2 compliant
• high efficiency 12 V DC switching mode power supply, requiring no mains transformer
• 4 A total output current
• short circuit and overload protection
• designed for use with sealed lead-acid batteries
• optionally selected battery charging current
• battery deep discharge protection
• 3 OC outputs for trouble indication
• optical indication of mains, battery and overload status
• audible trouble signal
• dedicated connector for use with new SATEL modules
• designed for mounting on DIN 35 mm rail and in OPU-3 P, OPU-4 P and OPU-4 PW enclosures
• battery disconnecting to prevent deep discharge
• compatible with all alarm panels not equipped with such feature
• cable to connect ETHM-1 and ETHM-1 Plus modules to the VERSA central control panel
• compatible with the OPAL Plus and OPAL Pro outdoor detectors
• remote sensitivity configuration of PIR and MW detection paths and dusk sensor
• support for single door with entry and exit authorization
• standalone or ACCO/ACCO NET system operation mode
• 1024 users
• user rights definition
• access authorization with proximity card and/or code
• 256 schedules
• holiday schedules
• non-volatile 24 576 event log
• work time registration event tagging
• anti-passback
• programming means:
○ permanently or temporarily connected LCD keypad
○ PC connected via RS-232 port
○ PC connected via ACCO-USB interface to RS-485 bus
• non volatile settings memory
• FLASH based firmware update
• scheduled door locking and unlocking
• programmable limits on number of accesses
• support for up to 255 access control modules
• ability to create up to 255 partitions in 1 control panel (up to 255 access control modules can be defined in one partition)
• ability to add up to 16 passageways (up to 16 partitions can be defined in each passageway)
• 8 programmable zones on the control panel board, expandable to 264 zones
• 8 programmable outputs on the control panel board, expandable to 264 outputs
• 2 high-current outputs on the control panel mainboard, with power output functionality (current-carrying capacity of each output: 0.5 A / 12 V DC ± 15%)
• ability to connect up to 32 expanders directly to the control panel: INT-E, INT-O, INT-PP, INT-RX-S
• electrical protection of all zones and outputs as well as communication buses
• connector for APS-412 or APS-612 backup power supply
• USB MINI-B port for configuring network settings and updating firmware of the control panel without having to disassembly it
• LED status indicators for:
○ communication between the control panel and the RS-485 buses, computer and server
○ power supply circuit
○ microSD card
• events are stored in non-volatile memory of the control panel:
○ up to 1,000,000 events from the control panel
○ 100,000 events from each access control module
• number of users: 8,000 in the control (65,000 in the whole system)
• each user can be assigned:
○ code
○ passive transponder (e.g. in the form of proximity card or key tag)
○ Dallas chip (iButton)
○ remote control keyfob
• ability to assign 4 identifiers and 1 keyfob to a single user
• access to certain partitions within a specified time interval
• ability to block/unblock partition at a specified time, or as per access schedule
• implementation of logic functions on zones and outputs
• support for turnstiles
• ability to control the control panel outputs by using keyfobs
• optional installation of the control panel in OPU-3 P or OPU-4 P enclosureSATEL failure to the control panel (INTEGRA Firmware 1.16 or newer)
• TCP/IP reporting receiver for SATEL Ethernet and GPRS transmitters
• support for up to 256 subscribers with individual link supervision
• hardware event buffering
• ETHERNET link supervision
• optional incoming events filtering based on physical address (MAC)
• support for automatic IP address configuration with DHCP
• possibility to install in computer's PCI slot
• built-in LCD for easy day-to-day operation and system programming,
• built-in backup power supply with a single battery 12 V 17 Ah, and AUX 24 V and 18 V power outputs
• selection of 32 signal sounds
• possibility of emitting two different sounds
• volume control
• high base for installation in installation tubes
نشانی: تهران، خیابان شهید بهشتی، خیابان کاووسی فر، پلاک 23